TT_FTX300LUXHG.png

3 Ch, High Gain for weaker signals

The FTX-300-LUX+HG fiber optic signal conditioner offers exceptional value combined with industry leading speed and accuracy. The FTX-300-LUX+HG transmitter is ideally suited for demanding research applications in MRI, microwave, and high electro-magnetic field environments. It can read optical sensors with tip diameters as small as 350 microns over distances up to 50 meters. It connects quickly to your personal computer with a standard USB cable to provide real-time temperature trending and data logging with the optional OSENSAView Pro software or LabView VI. The 4-20mA analog outputs have 16 bit resolution with configurable alarms for easy connection to a PLC, temperature controller, solid state relay, or digital display. Multiple signal conditioners can be connected in series and mounted on a standard 35mm DIN rail.


Product Specs

Number Of Channels
3
Analog Output
3
Digital Interface
USB & Isolated RS-485
Measurement Range
-70°C to +450°C
Resolution
0.01°C
System Accuracy
±0.05°C from 0 to 40°C Ambient
Update Rate
30-90 Hz
Certifications
UL, CE, ROHS

Fiber Optic Temperature Probes
MRI

1.5mm Nylon, 1000µm POF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Unnamed 10:
± 0.10°C
Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 100µm GOF

Fiber Optic Temperature Probes
Laser Ablation

0.23mm ETFE, 200µm GOF

Measurement Range:
-40°C to 80°C
Measurement Accuracy:
± 0.15°C
Jacket:
EFTE
Fiber Optic Temperature Probes
MRI, HIFU

0.23mm ETFE, 200µm GOF

Fiber Optic Temperature Probes
MRI, HIFU

0.23mm ETFE, 200µm GOF

Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 200µm GOF

Measurement Range:
-110°C to 150°C
Measurement Accuracy:
± 0.10°C
Typical Measurement Noise:
± 0.02°C
Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 200µm GOF

Measurement Range:
-40°C to 150°C
Measurement Accuracy:
± 0.10°C
Typical Measurement Noise:
± 0.01°C
Fiber Optic Temperature Probes
MRI

0.75mm Polyimide, 400µm GOF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
PVC & Polyimide
Fiber Optic Temperature Probes
MRI

0.7mm ETFE, 400µm GOF

Measurement Range:
-40°C to 150°C
Measurement Accuracy:
± 0.15°C
Jacket:
Polyimide & ETFE
Fiber Optic Temperature Probes
MRI

1.0mm Nylon, 500µm POF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
Nylon
Fiber Optic Temperature Probes
Motors & Generators

2.3mm Nylon, 1000µm POF

Measurement Range:
-40°C to +120°C
Measurement Accuracy:
±1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
Motors & Generators

2.3mm FEP, 1000µm GOF

Measurement Range:
-40°C to 200°C
Measurement Accuracy:
± 1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
Motors & Generators

2.3mm FEP, 1000µm GOF

Measurement Range:
-40°C to 200°C
Measurement Accuracy:
± 1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
MRI

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
Polyimide & PTFE
Fiber Optic Temperature Probes
Microwave, Induction Heating

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40 to +250°C
Bend Radius:
40mm
Max Length:
0.5 to 10m (2.0m default)
Fiber Optic Temperature Probes
Microwave, Induction Heating

0.75mm Polyimide, 400µm GOF

Measurement Range:
-40 to +250°C
Bend Radius:
60mm
Max Length:
0.5 to 10m (2.0m default)
Fiber Optic Temperature Probes
MRI

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40°C to 120°C
Measurement Accuracy:
± 0.10°C
Jacket:
PTFE & Polyimide