TT_FTX300LUXHG.png

3 Ch, High Gain for weaker signals

The FTX-300-LUX+HG fiber optic signal conditioner offers exceptional value combined with industry leading speed and accuracy. The FTX-300-LUX+HG transmitter is ideally suited for demanding research applications in MRI, microwave, and high electro-magnetic field environments. It can read optical sensors with tip diameters as small as 350 microns over distances up to 50 meters. It connects quickly to your personal computer with a standard USB cable to provide real-time temperature trending and data logging with the optional OSENSAView Pro software or LabView VI. The 4-20mA analog outputs have 16 bit resolution with configurable alarms for easy connection to a PLC, temperature controller, solid state relay, or digital display. Multiple signal conditioners can be connected in series and mounted on a standard 35mm DIN rail.


Product Specs

Number Of Channels
3
Analog Output
3
Digital Interface
USB & Isolated RS-485
Measurement Range
-70°C to +450°C
Resolution
0.01°C
System Accuracy
±0.05°C from 0 to 40°C Ambient
Update Rate
30-90 Hz
Certifications
UL, CE, ROHS

Fiber Optic Temperature Probes
MRI

1.5mm Nylon, 1000µm POF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Unnamed 10:
± 0.10°C
Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 100µm GOF

Measurement Range:
-40°C to 150°C
Measurement Accuracy:
± 0.10°C
Jacket:
ETFE
Fiber Optic Temperature Probes
Laser Ablation

0.23mm ETFE, 200µm GOF

Measurement Range:
-40°C to 80°C
Measurement Accuracy:
± 0.15°C
Jacket:
EFTE
Fiber Optic Temperature Probes
MRI, HIFU

0.23mm ETFE, 200µm GOF

Measurement Range:
-40°C to 80°C
Measurement Accuracy:
± 0.15°C
Jacket:
Polyimide & ETFE
Fiber Optic Temperature Probes
MRI, HIFU

0.23mm ETFE, 200µm GOF

Measurement Range:
-95°C to 80°C
Measurement Accuracy:
± 0.25°C
Jacket:
Polyimide & ETFE
Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 200µm GOF

Measurement Range:
-40°C to 150°C
Measurement Accuracy:
± 0.10°C
Jacket:
ETFE
Fiber Optic Temperature Probes
MRI, HIFU

0.50mm ETFE, 200µm GOF

Measurement Range:
-200°C to 150°C
Measurement Accuracy:
± 0.10°C
Typical Measurement Noise:
± 0.01°C
Fiber Optic Temperature Probes
MRI

0.75mm Polyimide, 400µm GOF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
PVC & Polyimide
Fiber Optic Temperature Probes
MRI

0.7mm ETFE, 400µm GOF

Measurement Range:
-40°C to 150°C
Measurement Accuracy:
± 0.15°C
Jacket:
Polyimide & ETFE
Fiber Optic Temperature Probes
MRI

1.0mm Nylon, 500µm POF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
Nylon
Fiber Optic Temperature Probes
Motors & Generators

2.3mm Nylon, 1000µm POF

Measurement Range:
-40°C to +120°C
Measurement Accuracy:
±1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
Motors & Generators

2.3mm FEP, 1000µm GOF

Measurement Range:
-40°C to 200°C
Measurement Accuracy:
± 1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
Motors & Generators

2.3mm FEP, 1000µm GOF

Measurement Range:
-40°C to 200°C
Measurement Accuracy:
± 1.0°C
Maximum Rating:
38 kV, 3 phase
Fiber Optic Temperature Probes
MRI

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40°C to 100°C
Measurement Accuracy:
± 0.10°C
Jacket:
Polyimide & PTFE
Fiber Optic Temperature Probes
Microwave, Induction Heating

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40 to +350°C
Bend Radius:
40mm
Max Length:
0.5 to 10m (2.0m default)
Fiber Optic Temperature Probes
Microwave, Induction Heating

0.75mm Polyimide, 400µm GOF

Measurement Range:
-40 to +350°C
Bend Radius:
60mm
Max Length:
0.5 to 10m (2.0m default)
Fiber Optic Temperature Probes
MRI

0.45mm Polyimide, 200µm GOF

Measurement Range:
-40°C to 120°C
Measurement Accuracy:
± 0.10°C
Jacket:
PTFE & Polyimide